HEAT EXCHANGERS

Heat produce by PROMONT based on copper tubing and aluminium fins provide the right temperature and humidity for mushroom production hall. Heat capacity soecified by us, based on years of experience,

 

 Depending on the need:

- water heaters or steam
- water coolers or freon

 

 

 

The heater and cooling support page should always be on the one side, left or right. To maintain maximum efficiency of heater and cooling medium should be connected so that the heat exchangers operated in a countercurrent system, ie so that the fluid flow takes places in the opposite direction to the flow of air.

 

 

 

Poniżej zestawiono standardowe wymienniki montowane w agregatach typu AGEP wraz ze średnicami króćców przyłączeniowych do instalacji hydraulicznej G”. 

 

Type
aggregate

EXCHANGERS

Water cooler

Water heater

120

CW 12KZ/19T-08R-0590A-25P-15NC

NW 16KZ/11T-02R-0590A-30P-03NC

200

CW 12KZ/22T-08R-0690A-25P-22NC

NW 16KZ/13T-02R-0690A-30P-03NC

300

CW 12KZ/26T-08R-0790A-25P-26NC

NW 16KZ/15T-02R-0790A-28P-03NC

400

CW 12KZ/31T-08R-0990A-25P-31NC

NW 16KZ/18T-02R-0990A-32P-06NC

600

CW 12KZ/31T-08R-1490A-25P-62NC

NW 16KZ/18T-02R-1490A-25P-09NC

800

CW 12KZ/31T-08R-1690A-25P-62NC

NW 16KZ/18T-02R-1690A-25P-09NC

1100

CW 12KZ/47T-08R-1490A-25P-94NC

NW 16KZ/27T-02R-1490A-30P-11NC

1500

CW 12KZ/47T-08R-1590A-25P-94NC

NW 16KZ/27T-02R-1590A-28P-13NC

 

Type
aggregate

pipe connector G”

Cooler

Heater

120

Cu 42mm / 1½

Cu 22mm / ¾˝

200

Cu 54mm / 2˝

Cu 22mm / ¾˝

300

 Cu 54mm / 2˝

Cu 28mm / 1˝

400

 Cu 54mm / 2˝

Cu 35mm / 1¼˝

600

 St 80mm / 3˝

Cu 42mm / 1½˝

800

 St 80mm / 3˝

Cu 54mm / 2˝

1100

 St 80mm / 3˝

Cu 54mm / 2˝

1500

 St 100mm / 4˝

Cu 54mm / 2˝

 