Data technical aggregates:
| Type | heating | power cooler | air preformance | accumulation fun | engine | heating water flow / pressure loss. [l/s]/[kPa] | cooling water flow / pressure loss [l/s]/[kPa] | Weight[kg] |
| 120 | 20 | 34 | 2500 | 400 | 0,75 | 0,31/5,05 | 1,33/18,07 | 120 |
| 200 | 35 | 50 | 4000 | 600 | 1,1 | 0,47/13,47 | 2,03/16,02 | 160 |
| 300 | 50 | 80 | 6000 | 600 | 1,5 | 0,64/19,95 | 2,64/21,84 | 200 |
| 400 | 70 | 100 | 8000 | 600 | 3,0 | 0,89/8,94 | 4,08/24,46 | 300 |
| 600 | 120 | 154 | 12000 | 650 | 2x3,0 | 1,64/11,70 | 6,11/17,78 | 550 |
| 800 | 160 | 200 | 16000 | 700 | 2x3,0 | 2,06/14,82 | 8,00/31,48 | 670 |
| 1100 | 180 | 260 | 21000 | 800 | 7,5 | 2,63/10,71 | 10,36/28,06 | 850 |
| 1500 | 220 | 300 | 25000 | 900 | 15,0 | 2,81/15,67 | 12,11/28,09 | 900 |
| Performance given with speed air on the exchangers w = 2,5 m/s and following parameters: - heater: water 80/60oC (air input: t = -5oC, ∆T = 25oC) | ||||||||